docs(beszel): document Beszel API types and field semantics

Add JSDoc comments to all Beszel PocketBase API types explaining the
cryptic short field names (cpu, mu, du, dr, ns, b, etc.), their units
(bytes, bytes/s, percentages), and the distinction between ns/nr
(all-interface traffic) vs b (public interface bandwidth).

Also documents the mapToSystemRow mapping and chart data extractors
so future readers understand the data flow without needing Beszel
source code.
This commit is contained in:
Thomas Camlong committed 2026-06-08 16:00:15 +02:00
1 parent c1bd6cccaa
commit bb96ca354f
4 files changed
+137

No files matched your search

@@ -57,6 +57,8 @@ export default function BeszelSystemStatsWidget({
includeDocker: showDocker,
});
// BeszelSystemStats fields are documented in beszel-types.ts.
// mu/du = bytes, dr/dw = bytes/s, b = public bandwidth [sent,recv] bytes/s, ns/nr = all-interface bytes/s
const BYTES_TO_GB = 1024 * 1024 * 1024;
const cpuMap = useCallback((s: { cpu: number }) => ({ [t("chart.cpu.series")]: s.cpu }), [t]);
@@ -75,6 +77,7 @@ export default function BeszelSystemStatsWidget({
}),
[t],
);
// b = public interface bandwidth (preferred), ns/nr = all-interface traffic (fallback)
const networkMap = useCallback(
(s: { ns: number; nr: number; b?: [number, number] }) => ({
[t("chart.network.sent")]: s.b?.[0] ?? s.ns,
@@ -82,6 +82,7 @@ export const useContainerNames = (containerStats: BeszelContainerStatsRecord[] |
type ContainerExtractor = (container: BeszelContainerStatsRecord["stats"][number] | undefined) => number;
// c = CPU (%), m = memory (bytes), b = bandwidth [sent,recv] (bytes/s), ns/nr = legacy net (bytes/s)
const defaultContainerExtractors: Record<string, ContainerExtractor> = {
cpu: (c) => c?.c ?? 0,
memory: (c) => c?.m ?? 0,